Fabric

MPI on InfiniBand and on Spectrum-X: what transfers and what does not

The MPI layer looks identical on both. Everything underneath it is different, and on the Ethernet side a single hop configured wrongly degrades collectives across the entire fabric while every link reports healthy.

11 min readRoCESpectrum-XInfiniBandPFCECNDCQCN

Running MPI over an Ethernet fabric with RoCEv2 and running it over InfiniBand look the same from the application. Same verbs API, same UCX, same Open MPI, same OSU benchmarks, same ib_write_bw. The adapter presents an /sys/class/infiniband/ device either way, which is why so much tooling appears to be portable.

What is not portable is everything that makes the fabric lossless, and that is where the operational differences live. On InfiniBand, link-level flow control is built into the architecture and is on by default. On Ethernet it is a configuration you have to get right on every port of every switch and every NIC in the path, and getting it wrong on one hop degrades the whole fabric.

The concept mapping

InfiniBand Ethernet / RoCEv2
Subnet manager assigns LIDs and computes routes No SM. L3 routing, BGP/ECMP, ARP and neighbour discovery
Credit-based link flow control, always on PFC (802.1Qbb) per priority, configured per port
Congestion control notification (CCT/CCTI), rarely enabled ECN marking plus CNP, and DCQCN on the NIC — normally mandatory
ibstat, iblinkinfo, ibdiagnet, perfquery ethtool -S, mlnx_qos, lldpctl, switch telemetry
Path MTU 256–4096, negotiated RoCE MTU derived from the L2 MTU; jumbo frames needed for 4096
Static routing by default; adaptive routing a switch feature ECMP by flow hash; Spectrum-X adds per-packet adaptive routing
Fabric is a single administrative object Fabric is an IP network, with everything that implies

Everything in the left column that you know how to use has an equivalent in the right column that behaves differently enough to catch you out.

What Spectrum-X changes about the Ethernet side

Plain RoCEv2 on general-purpose Ethernet is workable and fragile. The fragility comes from two places: PFC is a blunt instrument that spreads congestion backwards through the fabric, and ECMP hashes flows onto links, so a small number of large elephant flows — which is exactly what a collective produces — can collide on one link while others sit idle.

Spectrum-X addresses both. The switch performs adaptive routing at packet granularity rather than flow granularity, spreading a single flow’s packets across available paths, and the NIC handles the resulting out-of-order arrival and places data correctly without the sender having to care. Congestion control is done in coordination between switch telemetry and the NIC rather than by the generic DCQCN loop alone.

The practical consequence for MPI is that the ECMP collision problem — the one that makes plain RoCE alltoall performance erratic — is substantially addressed by the platform rather than by your hashing configuration. The PFC and ECN configuration discipline does not go away.

Treat the specific feature names and defaults for your switch OS release as authoritative over anything written here. What is stable is the shape of the problem, not the syntax.

PFC, and why one hop matters

Priority Flow Control sends a PAUSE frame for a specific traffic class when a port’s ingress buffer for that class fills. It is hop-by-hop: the upstream device stops sending that class until the pause expires or is canceled.

Two properties make it treacherous.

It is per-priority, and the priority has to match end to end. The NIC marks RoCE traffic with a DSCP value or a PCP value; the switch maps that to a traffic class; PFC is enabled on that class. Break the chain at any point — one switch that trusts PCP where the NIC is marking DSCP, one port where PFC was never enabled on priority 3, one uplink that was added later from a different template — and RoCE traffic on that hop lands in a lossy class. It then drops under congestion.

A drop is far more expensive than it looks. RoCE’s reliable connection transport recovers from loss, but recovery costs a round trip and, on older implementations, a retransmission of everything after the lost packet. A drop rate that would be invisible to TCP is enough to flatten collective performance.

And because a collective completes when its slowest participant completes, a single misconfigured hop that affects a handful of flows degrades the whole job. This is the mechanism behind the most confusing class of RoCE incident: every link is up, no interface shows errors, throughput between any two nodes you test is fine, and the alltoall is half what it should be.

Checking the chain

On the NIC:

mlnx_qos -i enp1s0f0
DCBX mode: OS controlled
Priority trust state: dscp
Cable len: 7
PFC configuration:
	priority    0   1   2   3   4   5   6   7
	enabled     0   0   0   1   0   0   0   0

Two lines matter. Priority trust state must agree with what the switch is trusting. PFC configuration must have the RoCE priority enabled and must agree with the switch’s per-port configuration.

Set it explicitly rather than inheriting:

mlnx_qos -i enp1s0f0 --trust dscp
mlnx_qos -i enp1s0f0 --pfc 0,0,0,1,0,0,0,0

Confirm what the RoCE traffic is actually marked with:

cat /sys/class/net/enp1s0f0/ecn/roce_np/cnp_dscp
cma_roce_tos -d mlx5_0

Then read the pause counters after a run. These are the evidence that PFC is being exercised, and whether it is being exercised on the priority you intended:

ethtool -S enp1s0f0 | grep -E 'prio[0-7]_(pause|buf_discard)'
rx_prio3_pause: 148213
rx_prio3_pause_duration: 3320119
tx_prio3_pause: 96204
tx_prio3_pause_duration: 1904772
rx_prio0_buf_discard: 0
rx_prio3_buf_discard: 0

Read it as follows. Pause counts on priority 3 that are non-zero and growing mean PFC is active and congestion is real — that is the mechanism working, not a fault, though sustained heavy pausing means the fabric is oversubscribed for the offered load. A non-zero buf_discard on the RoCE priority means packets were dropped in a class that was supposed to be lossless, which is a configuration failure. And pause counters on priority 0 while RoCE was running means your traffic is not in the class you think it is.

The counter that most often reveals the problem is rx_prio0_pause being non-zero on a fabric that was configured for RoCE on priority 3. It means the marking or the trust mode is wrong somewhere, and the traffic is being pause- controlled — or not — in the default class. Every link is up, nothing logs an error, and the collectives are poor.

ECN and DCQCN

PFC stops congestion at the cost of pushing it upstream. ECN is the mechanism that instead tells the sender to slow down, and it is what you want doing most of the work, with PFC as the last resort that prevents loss.

The loop: the switch marks packets ECN-CE when its queue exceeds a threshold; the receiving NIC sees the mark and returns a Congestion Notification Packet; the sending NIC reduces its rate for that queue pair and then recovers according to the DCQCN parameters.

The switch side is a WRED-style configuration with a minimum threshold, a maximum threshold and a marking probability, per queue. Those numbers are the main tuning lever and they interact with buffer size, link rate and round-trip time, so they are genuinely site-specific — a setting tuned for a two-tier 100 GbE fabric is not right for a 400 GbE one.

The NIC side lives in sysfs:

ls /sys/class/net/enp1s0f0/ecn/roce_np/    # notification point (receiver)
ls /sys/class/net/enp1s0f0/ecn/roce_rp/    # reaction point (sender)

cat /sys/class/net/enp1s0f0/ecn/roce_np/enable/3
cat /sys/class/net/enp1s0f0/ecn/roce_rp/enable/3

Both must be enabled on the RoCE priority, on every node. A node with the reaction point disabled does not slow down when told to, which means it wins against its better-behaved neighbours and drives the fabric into PFC. One such node in a large allocation is enough to make the whole job’s timing erratic, and it is a difficult thing to suspect if you are not looking for it.

The counters that show the loop working:

ethtool -S enp1s0f0 | grep -E 'cnp|ecn'
np_ecn_marked_roce_packets: 41229
np_cnp_sent: 40871
rp_cnp_handled: 39655
rp_cnp_ignored: 0

np_ecn_marked_roce_packets rising means the switch is marking, so ECN is configured on the switch and the path. np_cnp_sent should track it closely. rp_cnp_handled rising on the senders means they are reacting. rp_cnp_ignored being non-zero means CNPs are arriving for queue pairs that no longer exist or in a state where they cannot be acted on, and a large value is worth investigating.

The failure signature to recognize: marking is happening, CNPs are being sent, and rp_cnp_handled is zero or near it. The sending side is not reacting — the reaction point is disabled, or the CNPs are being lost or misclassified on the return path. CNPs themselves are typically marked with a different DSCP and should be in a high-priority, non-paused class; if they are queued behind the congestion they are meant to relieve, the control loop does not close.

There are also hardware counters on the RDMA device side, which are per-device rather than per-netdev and sometimes easier to correlate with a specific job:

grep . /sys/class/infiniband/mlx5_0/ports/1/hw_counters/* | \
  grep -E 'out_of_buffer|out_of_sequence|packet_seq_err|local_ack_timeout_err|rnr_nak|np_cnp|rp_cnp|roce_adp_retrans'

packet_seq_err and out_of_sequence are the ones to watch. On a fabric that is genuinely lossless they stay near zero. On Spectrum-X with packet-level adaptive routing, out-of-order arrival is expected and handled, so interpret these against the platform’s own guidance rather than against an InfiniBand intuition.

MTU

This is a small thing that costs a lot of bandwidth.

RoCE selects a path MTU from the standard set — 256, 512, 1024, 2048 or 4096 bytes — and it cannot exceed what the underlying Ethernet MTU can carry once headers are accounted for. If any hop in the path is at the default 1500, the RoCE MTU drops to 1024, and you lose a meaningful fraction of achievable bandwidth to per-packet overhead and processing.

The requirement is jumbo frames configured consistently on every NIC and every switch port in the path, typically 9000. One port left at 1500 — a newly added uplink, a replaced switch, a host that did not get the configuration — is enough.

Confirm what was negotiated rather than what was configured:

ib_write_bw -d mlx5_0 -x 3 -F -a --report_gbits <server>   # header prints Mtu
ip link show enp1s0f0 | grep mtu

The -x 3 selects a GID index, which on RoCE selects the RoCEv2 IPv4 or IPv6 entry. Get it from:

show_gids

Picking the wrong GID index is how people accidentally benchmark RoCEv1, or run over link-local IPv6 when they meant to use the routed IPv4 address.

What transfers between the two worlds

Transfers cleanly: the MPI layer entirely — Open MPI, MPICH, UCX, PMIx, the OSU benchmarks, your application. perftest works on both with the addition of a GID index. NCCL works on both, and refers to RoCE devices through the same NCCL_IB_HCA variable, which confuses people into thinking they have InfiniBand. The layered testing order from the first article in this series applies without modification.

Does not transfer: ibstat, iblinkinfo, ibdiagnet, ibnetdiscover, perfquery, opensm and everything built on LIDs and the subnet manager. There is no routing engine to choose and no LID budget to compute. In their place you have per-priority counters, switch telemetry, LLDP for topology discovery, and whatever your switch vendor’s fabric management provides.

Transfers, but means something different: latency figures. RoCE adds UDP/IP encapsulation and the congestion-control loop, and end-to-end small-message latency is generally higher than InfiniBand at an equivalent rate. How much depends on the NIC generation and the switch, so measure it with ib_send_lat on your own hardware rather than accepting a figure. The gap has narrowed considerably across recent generations; it has not closed.

Transfers, but with a different failure mode: congestion. On InfiniBand, credit-based flow control makes the fabric lossless without configuration, and a congested fabric slows down. On Ethernet, an incorrectly configured fabric drops, and RoCE recovery from drops is expensive enough that the performance cliff is steep rather than gradual. That difference — gradual degradation versus a cliff — is the single most important thing to internalize when moving MPI workloads from one to the other.

A minimum acceptance check on the Ethernet side

Before believing any MPI number on a RoCE fabric:

  1. mlnx_qos -i <dev> on every node — trust mode and PFC priority identical everywhere.
  2. ecn/roce_np/enable/<prio> and ecn/roce_rp/enable/<prio> set on every node.
  3. MTU 9000 confirmed on every host interface and every switch port in the path, and RoCE MTU 4096 confirmed in the ib_write_bw header.
  4. show_gids — the GID index in use is the RoCEv2 entry you intended.
  5. Clear counters, run a full-scale alltoall, then check every node for buf_discard on the RoCE priority and rp_cnp_handled moving. Any discard on the lossless class is a stop-and-fix.

That takes half an hour and it is the difference between a fabric that performs predictably and one that performs well on Tuesday.