Multi-rail MPI: making the second adapter carry its share

A second rail is bought as a doubling and usually arrives as something well short of it. The reasons are enumerable, most of them are in the host rather than the fabric, and the first thing to establish is whether MPI is using the second adapter at all.

11 min readMPIUCXMulti-railNUMARDMA

Dual-rail hosts are now the default on anything built for AI and common on general HPC nodes. Two adapters, two cables, two ports on the leaf, and a reasonable expectation that a bandwidth-bound job goes twice as fast.

It rarely does, and the gap between what was bought and what arrives is attributed to fabric overhead far more often than it deserves. In practice, the second rail underdelivers for one of a short list of reasons, most of which are inside the node and all of which are measurable.

First: is the second rail carrying anything at all?

Before tuning anything, establish whether the second adapter is being used. This is not a rhetorical question — a substantial fraction of dual-rail nodes in production are running every byte over one rail, and nothing reports it.

The direct method is the port counters. Clear, run, read:

for d in mlx5_0 mlx5_1; do
  echo -n "$d before: "
  cat /sys/class/infiniband/$d/ports/1/counters/port_xmit_data
done

mpirun -np 2 -map-by ppr:1:node ./osu_bw -m 8388608:8388608

for d in mlx5_0 mlx5_1; do
  echo -n "$d after: "
  cat /sys/class/infiniband/$d/ports/1/counters/port_xmit_data
done

If mlx5_1 did not move, you have a single-rail cluster with a spare adapter in it. That is a two-minute check and it settles the question that the rest of the work depends on.

Do this check before any tuning conversation. A node whose second adapter has never transmitted a byte is not a multi-rail tuning problem, and the discussion about striping thresholds and rendezvous rails that usually follows is entirely beside the point. The counter delta settles it in two minutes.

The second method is to ask UCX what it selected:

mpirun -np 2 -map-by ppr:1:node \
  -x UCX_LOG_LEVEL=info \
  ./osu_bw 2>&1 | grep -iE 'selected|device|transport|rndv'

Recent UCX releases also expose a protocol selection table that is considerably more readable than the log:

mpirun -np 2 -x UCX_PROTO_INFO=y ./osu_bw

It prints, per message-size range, which protocol and which devices UCX will use — including whether a large rendezvous transfer is being striped across multiple devices or sent over one. That table answers the multi-rail question directly rather than by inference.

Telling MPI which devices to use

UCX enumerates devices itself and its default selection is often not what you want, particularly on a node that also has a management NIC, a storage NIC, or an adapter whose port is administratively down.

ucx_info -d | grep -E '^#.*Transport|Device:'
ucx_info -v

The device list to hand to MPI is explicit and includes the port number:

mpirun -np 16 -map-by ppr:8:node --bind-to core \
  --mca pml ucx --mca osc ucx \
  -x UCX_NET_DEVICES=mlx5_0:1,mlx5_1:1 \
  -x UCX_TLS=rc_x,sm,self \
  ./osu_bw

Three parameters do most of the work:

  • UCX_NET_DEVICES — the allowlist. Naming devices explicitly is better practice than relying on discovery, because discovery changes when a port goes down or a card is added.
  • UCX_MAX_RNDV_RAILS — how many devices a single large (rendezvous) transfer may be striped across. The default has historically been 2. If you have four rails and want them all used by one transfer, this is the setting that is quietly capping you.
  • UCX_MAX_EAGER_RAILS — the same idea for the eager protocol used by smaller messages.

Confirm the values in effect rather than assuming the defaults:

ucx_info -f -c | grep -E 'MAX_RNDV_RAILS|MAX_EAGER_RAILS|NET_DEVICES|TLS'

Why the second rail underdelivers

Work through these in order. They are roughly ordered by how often they are the answer.

The transfer is not big enough to stripe. Rail striping applies to the rendezvous protocol. Messages below the rendezvous threshold go over one device. An application whose messages are all 64 KB will not benefit from a second rail no matter how it is configured, and that is a correct outcome rather than a misconfiguration. Check where your application’s message sizes sit before concluding anything.

Both adapters are on the same NUMA node. Two cards on one socket share that socket’s PCIe root complex, its memory bandwidth, and its inter-socket link for any traffic sourced from the other socket. Check:

for d in /sys/class/infiniband/mlx5_*; do
  echo "$(basename $d): numa_node=$(cat $d/device/numa_node)"
done
lstopo --output-format txt
nvidia-smi topo -m     # on GPU nodes: also shows GPU-to-HCA affinity

nvidia-smi topo -m is the one to read on a GPU node. PIX means the GPU and the adapter sit under the same PCIe switch, which is the case GPUDirect RDMA is designed for. NODE means same NUMA node but traversing the root complex. SYS means the traffic crosses the inter-socket link, and on that pairing the second rail is a good deal less than a second rail.

The ranks are not bound to the rail that is local to them. This is the common and fixable case. If every rank uses both rails, half of every node’s traffic crosses the inter-socket link. The better arrangement on a two-socket, two-rail node is that ranks on socket 0 use mlx5_0 and ranks on socket 1 use mlx5_1, with no striping at all. That is not multi-rail in the striping sense; it is rail affinity, and it usually outperforms naive striping.

A small wrapper does it, driven by the local rank the launcher exports:

#!/bin/bash
# rail-bind.sh - one rail per socket, selected by node-local rank
local_rank=${OMPI_COMM_WORLD_LOCAL_RANK:-${SLURM_LOCALID:-0}}
half=$(( OMPI_COMM_WORLD_LOCAL_SIZE / 2 ))
if [ "$local_rank" -lt "$half" ]; then
  export UCX_NET_DEVICES=mlx5_0:1
else
  export UCX_NET_DEVICES=mlx5_1:1
fi
exec "$@"
mpirun -np 32 -map-by ppr:8:numa --bind-to core ./rail-bind.sh ./osu_mbw_mr

Measure both arrangements. Which wins depends on the message-size distribution and on whether the application is bandwidth- or latency-bound, and it is not predictable from the topology alone.

The PCIe slots cannot carry it. Two NDR400 adapters is 100 GB/s of offered load in each direction. Confirm both slots trained to their rated speed and width, and confirm the platform is not sharing lanes between them:

lspci -vv | grep -A1 Mellanox | grep -E 'LnkCap|LnkSta'

Both rails land on the same leaf switch and the same uplinks. This is the fabric-side case, and it is why some sites deliberately build the second rail as a separate subnet with its own switches and its own subnet manager. If both rails leave the node, arrive at the same leaf, and take the same uplinks to the spine, the second rail doubles the host’s egress capacity and does nothing for the fabric’s ability to carry it. Check where each rail’s port actually lands:

ibnetdiscover | grep -A2 "$(ibstat mlx5_0 | awk '/Port GUID/{print $3}')"
iblinkinfo -l | grep -iE 'node01'

The application is not bandwidth-bound. A latency-bound code gains nothing from a second rail and may lose a little to the extra selection logic. This is the outcome nobody wants to hear and it is frequently the correct one. It is also the argument for measuring with osu_mbw_mr at your application’s real message sizes rather than with a large-message osu_bw that flatters the configuration.

Proving RDMA is engaged, not TCP over IPoIB

Silent fall back to TCP over IPoIB is the single most consequential quiet failure in this area. Everything works. The job completes. The bandwidth is roughly a tenth of what it should be and the latency is roughly ten times what it should be, and both of those are within the range of “the code doesn’t scale well,” which is what it gets recorded as.

There are three ways to establish the truth, in increasing order of how conclusive they are.

Read the counters. As above: if port_xmit_data on the InfiniBand device does not move during the run, the traffic is not on the InfiniBand transport. Corroborate on the IPoIB side, where it will have gone instead:

cat /sys/class/net/ib0/statistics/tx_bytes

Read the UCX transport selection. UCX_PROTO_INFO=y or UCX_LOG_LEVEL=info will name the transport. Seeing tcp where you expected rc_x or dc_x is the finding.

Remove the fallback and see if it still runs. This is the conclusive test, and it takes one flag:

mpirun -np 2 -x UCX_TLS=rc_x,sm,self ./osu_bw

That list contains no TCP transport. If the job runs, RDMA was working. If it fails to establish connections, TCP was carrying the traffic and now you know. Run this as a gate in your acceptance suite; it converts a silent degradation into a loud failure, which is the whole objective.

The usual root causes, once you have established fallback is happening:

Cause Check
Locked memory limit not raised ulimit -l inside the job, not on the login node
Device down or not present on some nodes ibstat across the whole allocation
UCX_NET_DEVICES naming a device that does not exist there Node-by-node device enumeration
Node with a different OFED or missing rdma-core ofed_info -s fleet-wide
Firewall or SELinux policy on a subset of nodes Compare a working and a failing node

ulimit -l deserves emphasis. Memory registration for RDMA requires locked pages, and if the limit is not unlimited inside the job’s environment, UCX cannot register buffers and falls back. The limit set in /etc/security/limits.d applies to login sessions; what matters is the limit inside the scheduler’s launched process, which can differ. Check it from inside a job:

srun -N 2 bash -c 'echo $(hostname) $(ulimit -l)'

Rail-optimized topologies

On AI clusters the multi-rail arrangement is often not “two rails to the same fabric” but a rail-optimized design: each GPU has an adapter, and adapter k on every node connects to switch k. Same-index GPUs across nodes then communicate within a single switch, which is what makes large all-reduces efficient.

Two consequences for MPI. First, the affinity between rank, GPU and adapter is not a tuning preference, it is the design, and getting it wrong sends traffic across the fabric that was supposed to stay in one switch. Second, if the rails are separate subnets, each has its own subnet manager and its own LID space, and tooling that assumes one fabric will report on one of them and silently ignore the rest.

Verify the mapping is what the cabling intended before benchmarking anything:

nvidia-smi topo -m
for d in /sys/class/infiniband/mlx5_*; do
  n=$(basename $d)
  printf '%s numa=%s lid=%s sm_lid=%s\n' "$n" \
    "$(cat $d/device/numa_node)" \
    "$(ibstat $n 1 | awk '/Base lid/{print $3}')" \
    "$(ibstat $n 1 | awk '/SM lid/{print $3}')"
done

What to measure, and in what order

  1. ib_write_bw -d mlx5_0 and -d mlx5_1 separately. Each rail alone should reach the same number. If one is lower, stop — that is a link or slot problem and it is not a multi-rail question.
  2. Both rails simultaneously, as two concurrent ib_write_bw processes pinned to the correct sockets. This is the host’s true aggregate ceiling and it is the number multi-rail MPI is trying to reach.
  3. osu_bw with one rail, then with both. Compare against step 2.
  4. osu_mbw_mr at your application’s message sizes, one rail versus both, with and without rail affinity.

Step 2 is the one that gets skipped, and it is the one that tells you whether the shortfall is in the host or in MPI. If two concurrent ib_write_bw processes cannot reach twice a single rail, no MPI configuration will, and you have a PCIe, NUMA or memory-bandwidth investigation rather than a UCX one.