An MPI troubleshooting playbook: symptom to cause

Hangs, stragglers, silent TCP fallback, launcher failures and results that change between runs. Each has a small set of causes and a command that distinguishes them, and most of the time lost is spent on the wrong layer.

13 min readMPIUCXPMIxTroubleshootingRDMA

This is the reference half of the series. The earlier articles argue for testing in a particular order; this one is the lookup table for when something is already broken and you need the shortest path to a cause.

The single most useful habit underneath all of it: capture the node list, the environment and the module versions with every run. Most of the diagnoses below are trivial with that information and genuinely difficult without it.

The index

Symptom Most likely causes First command
Hangs at MPI_Init PMIx mismatch, launcher, hostfile mpirun --mca plm_base_verbose 10
Hangs at first collective QP setup, memlock, one unreachable node srun -N all bash -c 'ulimit -l'
Runs, but ~10x slow Silent TCP fallback UCX_TLS=rc_x,sm,self
Fails only above N ranks RC queue-pair exhaustion, registration memory UCX_TLS=dc_x,sm,self
One rank always late Degraded link, throttled node, stray daemon Pairwize ib_write_bw sweep
Timings vary run to run Allocation varies, shared ISLs, jitter Record and compare node lists
Bandwidth exactly half Width negotiation, PCIe width, single rail iblinkinfo, lspci -vv
Retry exceeded errors Fabric drops, RoCE PFC/ECN, dead peer Port counters, ethtool -S
Worse after a maintenance window Firmware skew, routing engine fell back ibv_devinfo fleet-wide, SM log

Everything below expands one row.

Hangs at startup

A job that never reaches the application is a launcher problem, not a fabric problem, and the fabric tooling will waste your time here.

mpirun --mca plm_base_verbose 10 --mca rmaps_base_verbose 5 -np 4 hostname

That prints the launch sequence as it happens, and the point at which it stops is the diagnosis. Common stopping points:

Cannot reach a node. The launcher uses SSH or the scheduler’s own launch mechanism. If it is SSH, key-based access between compute nodes must work non-interactively, and on a cluster with pam_slurm_adopt it must work from within an allocation, which is not the same test as from the login node.

PMIx version mismatch. This is the common one on schedulers, and it produces either a hang or an error naming PMIX. Slurm and Open MPI are each built against a PMIx, and if the two disagree, srun-launched MPI jobs fail while mpirun-launched ones work, or vice versa. Establish what each side has:

srun --mpi=list
ompi_info | grep -iE 'pmix|prrte'
pmix_info --version

Then be explicit rather than relying on the default:

srun --mpi=pmix -N 2 -n 4 ./a.out

If srun --mpi=list does not offer a PMIx entry, Slurm was not built with PMIx support and mpirun under an allocation is your path.

“There are not enough slots available in the system.” The hostfile or the scheduler allocation says fewer slots than -np asked for. Under a scheduler, this usually means mpirun did not pick up the allocation. --oversubscribe silences it and does not fix it; check $SLURM_JOB_NODELIST and $SLURM_NTASKS instead.

Hangs at the first collective

Startup succeeded, ranks exist, and the job stops the first time they all have to talk. This is connection establishment.

Locked memory limit. RDMA needs pinned pages. If the limit is not unlimited inside the job, registration fails. The limit that matters is the one inside the launched process, which is not necessarily the one in /etc/security/limits.conf:

srun -N 8 --ntasks-per-node=1 bash -c 'echo $(hostname) $(ulimit -l)'

Anything other than unlimited on any node is the answer.

A node that is up but has no working adapter. The job launches everywhere and then waits for the one rank that cannot connect. Check the whole allocation rather than a sample:

srun -N $SLURM_NNODES --ntasks-per-node=1 bash -c \
  'echo "$(hostname) $(ibstat mlx5_0 1 | awk "/State:/{print \$2}" | head -1)"'

Firewall on the fabric interface. Rare on InfiniBand, common on RoCE, where the traffic is UDP and a host firewall will happily block port 4791.

To see where it is stuck rather than guessing, attach to a hung rank:

pstack $(pgrep -n a.out)          # or: gdb -p <pid> -batch -ex bt

A stack sitting in a UCX progress or connection-establishment function is a transport problem. A stack in application code is not.

Silent fall back to TCP

The most expensive quiet failure in MPI, because nothing is broken. The job completes, the numbers are bad, and the conclusion recorded is that the application does not scale.

The signature is quantitative: bandwidth roughly an order of magnitude below the link rate and small-message latency roughly an order of magnitude above what the fabric should give. If a two-node osu_bw on a 200 Gb/s fabric reports a couple of gigabytes per second, stop tuning and check the transport.

The conclusive test removes the fallback:

mpirun -np 2 -x UCX_TLS=rc_x,sm,self -x UCX_NET_DEVICES=mlx5_0:1 ./osu_bw

No TCP transport is listed. If the job runs, RDMA was working and the problem is elsewhere. If it fails to establish connections, TCP was carrying the traffic.

Corroborate by watching the device counters move — or not — during a run:

before=$(cat /sys/class/infiniband/mlx5_0/ports/1/counters/port_xmit_data)
mpirun -np 2 -map-by ppr:1:node ./osu_bw -m 8388608:8388608 >/dev/null
after=$(cat /sys/class/infiniband/mlx5_0/ports/1/counters/port_xmit_data)
echo "delta: $(( after - before ))"

Causes, in the order they are usually found: ulimit -l not unlimited; a device name in UCX_NET_DEVICES that does not exist on some nodes; a node with a different OFED; a port that is down on one node; and, on GPU nodes, a CUDA-aware build mismatch that causes UCX to reject the RDMA path for device buffers.

Put the UCX_TLS=rc_x,sm,self run in your acceptance suite as a pass/fail gate. It costs seconds and it converts the single most damaging silent degradation into a loud, obvious failure. Almost nobody does this, and it is the highest-value five lines in an MPI test harness.

Fails only above a certain scale

A job that works at 8 nodes and fails at 64 is usually a resource that scales with the square of the rank count.

Reliable Connection queue pairs. With RC, each rank maintains a QP to each peer it talks to. Full connectivity across n ranks is n² QPs, and each consumes adapter and host resources. On a node running many ranks, this becomes the constraint well before the fabric does.

Dynamically Connected transport solves it by multiplexing:

mpirun -x UCX_TLS=dc_x,sm,self -x UCX_NET_DEVICES=mlx5_0:1 ./a.out

If a job fails at high ranks-per-node with connection or resource errors and succeeds with dc_x, that was it. Note that DC availability depends on the adapter generation, and that the failure mode when DC resources themselves are exhausted is different and less obvious — usually a hang rather than an error.

Memory registration limits. Large registered regions need translation table entries. The relevant firmware parameters differ by adapter and driver generation; the symptom is a registration failure at a size or rank count that worked before.

Aggregate memory per node. Each connection carries buffers. At high ranks-per-node, MPI’s own buffer footprint becomes significant, and the job dies of OOM in a way that looks like an application memory bug. dmesg on the node that died settles it in one line.

One rank is always late

A collective takes as long as its slowest participant, so one degraded node degrades everything. Finding it is mechanical.

Bisection is fastest: split the allocation, run both halves, keep the slow half, repeat. Six rounds for 64 nodes.

The systematic version tests every node against one reference, at the verbs layer so MPI is not in the picture:

REF=node001
for n in $(scontrol show hostnames $SLURM_JOB_NODELIST); do
  [ "$n" = "$REF" ] && continue
  bw=$(ssh $n "ib_write_bw -d mlx5_0 -F -s 1048576 -D 5 --report_gbits $REF" \
        | awk '/1048576/ {print $4}')
  echo "$n $bw"
done | sort -k2 -n | head -5

Once you have the node, the causes are a short list:

  • Narrow or degraded link — iblinkinfo, mlxlink -d mlx5_0 -p 1 --show_fec.
  • Downtrained PCIe slot — lspci -vv | grep LnkSta.
  • CPU frequency capping or thermal throttling — turbostat, cpupower frequency-info, and dmesg | grep -i thermal.
  • A daemon on a core that a rank is pinned to.
  • Memory running at a lower speed, or a DIMM that failed into a degraded configuration — dmidecode -t memory, and the platform’s own health log.

On the last point about cores: aggregate CPU idle proves nothing on a many-core node. One rank spinning uselessly on a 192-core machine is half a percent of system-wide CPU. top shows a healthy node. Look per-core:

mpstat -P ALL 1 5
pidstat -t -p $(pgrep -n a.out) 1 5

Timings vary wildly between runs

Before treating variance as a signal, establish that it is not the experiment.

The allocation changed. Different nodes, different leaves, different number of spine crossings. This is the most common cause by a wide margin. Record scontrol show hostnames $SLURM_JOB_NODELIST with every result and compare.

Other jobs share the fabric. Exclusive node allocation does not give you exclusive links. Another job’s alltoall on the same spine uplinks changes your result, and you have no visibility into it from inside your job. If you are producing numbers that matter, get an exclusive fabric window, or at minimum record what else was running.

Cached or warm state. The first iteration of anything includes connection setup and memory registration. Every benchmark here has a warmup flag; use it. Where filesystem I/O is in the loop, a repeat run served from page cache is not a measurement of anything.

OS jitter. Unpinned ranks, an unsynchronized housekeeping daemon, a monitoring agent that wakes every thirty seconds. Collectives amplify jitter because every rank waits for the one that was interrupted. --bind-to core and --report-bindings first; if variance persists with clean binding, look at what runs on the compute nodes on a timer.

Power and frequency policy. A node that boosts for the first thirty seconds and then settles produces a benchmark whose result depends on its duration. Fix the governor for measurement runs and record what it was.

A run-to-run spread you cannot get under a few percent is not a slow cluster. It is an uncontrolled experiment, and no amount of tuning against it will converge.

Bandwidth that is a clean fraction of expectation

Half, a quarter, a tenth. Clean fractions have mechanical causes and are worth a minute of arithmetic before any investigation.

Fraction Look at
Exactly half Link width 2X not 4X; one rail of two in use; PCIe x8 not x16
Exactly a quarter Link width 1X; PCIe x4; two independent halvings
About a tenth TCP fallback, or IPoIB instead of RDMA
About 60 percent Often real — protocol overhead plus an unsaturated single rank
ibstatus mlx5_0 | grep rate
iblinkinfo -l | grep -v 4X
lspci -vv -s <bdf> | grep -E 'LnkCap|LnkSta'

MTU

On InfiniBand, path MTU is negotiated and normally 4096. On RoCE it is derived from the Ethernet MTU, and a single hop at 1500 anywhere in the path drops the RoCE MTU to 1024 with a real bandwidth cost.

The ib_write_bw header prints what was actually negotiated, which is the number to trust over any configuration file:

 Mtu             : 4096[B]

If that reads 1024 on a fabric you configured for jumbo frames, walk the path. The offender is usually a recently added switch port or a host whose interface configuration did not include the MTU.

IPoIB has its own version of this — datagram mode caps at 2044 bytes while connected mode allows much larger — which matters if any part of your workload, including the scheduler or the filesystem, is running over IPoIB.

After a maintenance window

Performance that changed after a window, with no application change, has a short suspect list.

Firmware skew. Some nodes were updated and some were not, or a node was replaced with one from a different batch. Group by PSID and compare within groups:

pdsh -w node[001-256] 'ibv_devinfo | grep -E "fw_ver|board_id"' | dshbak -c

The routing engine fell back. A switch that was down during the sweep, or a node cabled differently on the way back in, can make ftree decline the topology and fall back to updn for the entire fabric. The subnet manager logs it and nobody reads it:

grep -iE 'routing engine|fallback|ftree' /var/log/opensm.log | tail -40

A standby subnet manager took over. If the standby holds an older configuration, the whole fabric is now routed by that configuration. sminfo tells you which SM is master.

A driver or kernel change altered defaults. UCX and OFED defaults do move between releases. Diff the effective configuration, not the configuration files:

ucx_info -f -c > /var/tmp/ucx-$(date +%F).conf
diff /var/tmp/ucx-<previous>.conf /var/tmp/ucx-$(date +%F).conf

Error messages worth recognizing

IBV_WC_RETRY_EXC_ERR / “Retry exceeded”. The sender gave up after retransmitting. On InfiniBand, this usually means the peer died or a link went down mid-transfer. On RoCE, it much more often means the fabric is dropping — PFC not enabled on the RoCE priority, or a mismatched trust mode. Go to the per-priority discard counters.

RNR retry exceeded. The receiver had no buffer posted and kept saying so until the sender gave up. Usually an application or middleware issue rather than a fabric one, though severe congestion can produce it.

The fork() warning. Registered memory and fork() interact badly. If your application or a library it calls forks after registering memory, you get either a warning or corruption. ibv_fork_init and the corresponding MPI settings exist for this; a job that calls out to shell commands from inside a rank is the usual trigger.

UCX ERROR ... Connection reset by remote peer. A peer rank died. Find out why that rank died; the UCX error is a consequence, not a cause. Check dmesg on its node for OOM.

The habit that shortens all of this

Keep a baseline file, in version control, per cluster:

  • OFED, firmware and PSID per node group
  • PCIe LnkSta per adapter
  • ib_write_bw and ib_read_bw plateaus for a named intra-leaf and cross-spine pair
  • osu_latency at 8 bytes and osu_bw at 8 MB
  • Allreduce and alltoall curves at the job sizes you run, with node lists
  • The width-and-rate histogram for the whole fabric

Regenerate it after every maintenance window. Almost every diagnosis in this article becomes a diff against that file, and a diff takes minutes where an investigation takes days.